R32 split inverter heating cooling heat pump
Advantages of Split Air-to-Water Heat Pump
The split-type heat pumps are systems where the outdoor unit is connected to the indoor unit with refrigeration copper pipes. The indoor unit could be a hydraulic box or contain a buffer cylinder or together with a domestic hot water tank for sanitary purposes.
Benefits of the Split Heat Pump
● Heat Pump can work under extremely cold are
● The outdoor is compact for easy maintenance
● The outdoor is much lighter
● Noise is lower
Special Features of UltraHeat Mono
Certificates and Reports

Various Optional Application Systems

"Dual-zoning"HP System

Solar Heat Pump System

Space heating heat pump system

Space heating plus sanitary hot water system

Space heating, place cooling and sanitary hot water heat pump system

Space heating and domestic hot water with auxiliary heat source heat pump system
Technical Data Sheet for R32 Heat Pump-UltraHeat Split | |||||||||||||
Model | 4kW | 6kW | 8kW | 10kW | 10kW-3 phase | 12kW | 12kW-3 phase | 14kW | 14kW-3 phase | 16kW | 16kW-3 phase | ||
Outdoor model | TS32-04WEBP | TS32-06WEBP | TS32-08WEBP | TS32-10WEBP | TS32-10WEBP-T | TS32-12WEBP | TS32-12WEBP-T | TS32-14WEBP | TS32-14WEBP-T | TS32-16WEBP | TS32-16WEBP-T | ||
Indoor Model | TS32-04NEBP | TS32-06NEBP | TS32-08NEBP | TS32-10NEBP | TS32-10NEBP-T | TS32-12NEBP | TS32-12NEBP-T | TS32-14NEBP | TS32-14NEBP-T | TS32-16NEBP | TS32-16NEBP-T | ||
Basic Functions | House heating+house cooling+domestic hot water | ||||||||||||
Extra Hybrid Functions | SG Ready/combination with Solar thermal,gas boiler/WIFI+APP | ||||||||||||
General | |||||||||||||
Power supply | V / Ph / H | 220-240 / 1 / 50 | 380-415 /3 / 50 | 220-240 / 1 / 50 | 380-415 /3 / 50 | 220-240 / 1 / 50 | 380-415 /3 / 50 | 220-240 / 1 / 50 | 380-415 /3 / 50 | ||||
Compressor | Type | Twin rotary DC inverter | |||||||||||
Brand | Mitsubishi | ||||||||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Outdoor fan | Motor type | Brushless DC motor | |||||||||||
Number of fans | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Fan motor | Fan type | 3 blade | |||||||||||
Motor type | BLDC | ||||||||||||
Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Throttle type | Electronic expansion valve | ||||||||||||
Water side heat-exchanger | Plate heat exchanger | ||||||||||||
Piping connections | Type | Flare | Flare | Flare | Flare | Flare | Flare | Flare | Flare | Flare | Flare | Flare | |
Liquid Dia .(OD) | mm | Φ6.35 | Φ6.35 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | Φ9.52 | |
Gas Dia.(OD) | mm | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | Φ15.88 | |
Min.pipe length | m | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Max.pipe length | m | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | |
Isntallation height difference |
Outdoor unit above | m | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
Outdoor unit below | m | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | |
Anti-UV cover | NO | ||||||||||||
Water resistance | IPX4 | ||||||||||||
MOP(Maximum overcurrent protection) | A | 38 | 38 | 38 | 38 | 25 | 48 | 30 | 48 | 30 | 48 | 30 | |
MCA(Minimum circuit amps) | A | 25 | 27 | 29 | 32 | 20 | 39 | 24 | 40 | 25 | 40 | 26 | |
Water pressure drop | kPa | 25 | 25 | 39 | 37 | 37 | 36 | 36 | 38 | 38 | 38 | 38 | |
Net/Gross weight | INDOOR-Net/Gross | kg | 34/38 | 34/38 | 35/39 | 36/40 | 37/41 | 37/41 | 38/42 | 41/46 | 44/49 | 41/46 | 44/49 |
OUTDOOR-Net/Gross | kg | 51/62 | 51/62 | 53/64 | 67/78 | 77/87 | 75/85 | 80/90 | 93/108 | 102/117 | 93/108 | 102/117 | |
Dimension (L×W×H) | OUTDOOR-Net | mm | 982×425×712 | 1003×448×809 | 1104×492×860 | ||||||||
OUTDOOR-Packing | mm | 1025×465×865 | 1045×458×970 | 1165×500×1040 | |||||||||
INDOOR-Net | mm | 909×465×273 | 909×465×273 | 909×465×273 | |||||||||
INDOOR-Packing | mm | 960×525×345 | 960×525×345 | 960×525×345 | |||||||||
Heating Circuit | |||||||||||||
Heating1 (Outdoor air temperature 7℃ DB ,85% R.H ; EWT 30℃,LWT 35℃) |
Capacity | kW | 4.2 | 6.0 | 7.9 | 9.7 | 9.7 | 12.1 | 12.1 | 14.3 | 14.3 | 16.2 | 16.2 |
Rated input | kW | 0.86 | 1.23 | 1.75 | 2.10 | 2.10 | 2.68 | 2.68 | 3.10 | 3.10 | 3.67 | 3.67 | |
COP | 4.89 | 4.89 | 4.52 | 4.61 | 4.61 | 4.52 | 4.52 | 4.61 | 4.61 | 4.41 | 4.41 | ||
Heating2 (Outdoor air temperature 7℃ DB ,85% R.H ; EWT 40℃,LWT 45℃) |
Capacity | kW | 4.1 | 6.1 | 8.3 | 9.9 | 9.9 | 11.6 | 11.6 | 14.5 | 14.5 | 16.2 | 16.2 |
Rated input | kW | 1.18 | 1.70 | 2.41 | 2.83 | 2.83 | 3.66 | 3.66 | 3.89 | 3.89 | 4.48 | 4.48 | |
COP | 3.47 | 3.58 | 3.45 | 3.48 | 3.48 | 3.17 | 3.17 | 3.72 | 3.72 | 3.62 | 3.62 | ||
Heating3 (Outdoor air temperature 7℃ DB ,85% R.H ; EWT 47℃,LWT 55℃) |
Capacity | kW | 4.0 | 6.2 | 8.0 | 9.9 | 9.9 | 11.7 | 11.7 | 13.8 | 14.1 | 16.2 | 16.2 |
Rated input | kW | 1.65 | 2.18 | 2.96 | 3.58 | 3.58 | 4.30 | 4.30 | 4.42 | 4.52 | 5.59 | 5.59 | |
COP | 2.42 | 2.84 | 2.70 | 2.77 | 2.77 | 2.72 | 2.72 | 3.12 | 3.12 | 2.90 | 2.90 | ||
Operating temperature | Heating | ℃ | -25 to 35 | ||||||||||
DHW Operating temperature | DHW | ℃ | -25 to 43 | ||||||||||
Cooling Circuit | |||||||||||||
Cooling4 (Outdoor air temperature 35℃ DB ,85% R.H ; EWT 23℃,LWT 18℃) |
Capacity | kW | 4.2 | 6.2 | 8.1 | 10.3 | 10.3 | 12.1 | 12.1 | 13.5 | 13.5 | 14.9 | 14.9 |
Rated input | kW | 0.78 | 1.29 | 1.76 | 2.25 | 2.25 | 2.99 | 2.99 | 3.75 | 3.75 | 4.38 | 4.38 | |
EER | 5.41 | 4.81 | 4.59 | 4.58 | 4.58 | 4.04 | 4.04 | 3.65 | 3.65 | 3.41 | 3.41 | ||
Cooling5 (Outdoor air temperature 35℃ DB ,85% R.H ; EWT 12℃,LWT 7℃) |
Capacity | kW | 4.2 | 6.0 | 7.7 | 9.6 | 9.6 | 10.9 | 10.9 | 12.7 | 12.7 | 14.0 | 14.0 |
Rated input | kW | 1.35 | 2.04 | 2.77 | 3.26 | 3.26 | 4.09 | 4.09 | 4.98 | 4.98 | 5.71 | 5.71 | |
EER | 3.12 | 2.94 | 2.78 | 2.94 | 2.94 | 2.66 | 2.66 | 2.55 | 2.55 | 2.45 | 2.45 | ||
Operating temperature | Cooling | ℃ | -5 to 43 | ||||||||||
Efficiency | |||||||||||||
Seasonal space heating energy efficiency class |
LWT at 35℃ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |
LWT at 55℃ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | ||
SCOP | LWT at 35℃ | 4.88 | 4.90 | 4.61 | 4.82 | 4.82 | 4.70 | 4.73 | 4.56 | 4.98 | 4.56 | 4.87 | |
LWT at 55℃ | 3.40 | 3.36 | 3.20 | 3.21 | 3.41 | 3.37 | 3.47 | 3.33 | 3.49 | 3.36 | 3.69 | ||
SEER | LWT at 7℃ | 5.33 | 5.27 | 5.23 | 5.12 | 5.32 | 4.91 | 5.65 | 4.76 | 5.39 | 4.63 | 5.23 | |
LWT at 18℃ | 8.29 | 8.34 | 8.19 | 8.23 | 8.23 | 7.82 | 9.01 | 6.72 | 7.71 | 6.51 | 7.78 | ||
Refrigeration Circuit | |||||||||||||
Refrigerant system pressure (Max. / Min.) | 4.5MPa / 1.5MPa | ||||||||||||
Refrigerant | Type | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | |
Charged | kg | 1.40 | 1.40 | 1.50 | 1.60 | 1.60 | 1.75 | 1.75 | 1.84 | 1.84 | 1.84 | 1.84 | |
GWP value | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | ||
Equivalent CO2 | Ton | 0.945 | 0.945 | 1.013 | 1.080 | 1.080 | 1.181 | 1.181 | 1.241 | 1.241 | 1.241 | 1.241 | |
Noise emissions, heating mode | |||||||||||||
Sound power level (sound power) Test standard:EN12102-1 |
INDOOR | dB | 42 | 42 | 42 | 42 | 42 | 42 | 42 | 42 | 42 | 42 | 42 |
OUTDOOR | dB | 56 | 58 | 59 | 60 | 60 | 64 | 64 | 65 | 65 | 68 | 68 | |
Sound power level (sound pressure) Test standard:EN12102-1 |
INDOOR | dB | 42 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
OUTDOOR | dB | 42 | 46 | 47 | 48 | 48 | 49 | 49 | 50 | 50 | 51 | 51 | |
Container shipping quantity | |||||||||||||
20GP Container | pieces | 45 | 45 | 45 | 38 | 38 | 38 | 38 | 28 | 28 | 28 | 28 | |
40HQ Container | pieces | 92 | 92 | 92 | 85 | 85 | 85 | 85 | 60 | 60 | 60 | 60 |